safe-bar-code-positioning-system
Leuze德国

safe-bar-code-positioning-system

在产

The world's first safety bar code positioning system, FBPS 600i, requires just one sensor for safe position detection. The device is connected to a safe evaluation unit via two SSI interfaces or to a safety controller via PROFIsafe and is suitable for ap…

全部替代型号

查看完整报告

技术参数

环境与封装
Bar code grid dimension30 mm / 40 mm
Dimensions, W x H x DConnections on the side: 116.3 x 112.5 x 51.5 mm​ Bottom connections: 105 x 123.8 x 51.5 mm
Temperature range-5 ... +60°C With heating: -35…+60°C
其他
Configurable bar code tapesHeight: 20 mm to 140 mm Selectable start and end value ranging from 0 to 10,000 m Twin tape
Connection2x SSI interface: 2x M12 connector PROFINET/ PROFIsafe, opt. SSI: 2(3)x M12 connector Power supply: M12 connector Configuration and diagnosis: Mini USB
Display (optional)Display of position and status information
Error response time10 ms … 400 ms (adjustable)
FeaturesExtremely robust plastic tape, UV- resistant, self-adhesive with acrylic adhesive, position values printed in plain text
Protection classIP 65
Reading distance50 ... 170 mm
Reproducibility+/- 0.15 mm (1 sigma)
SafetySafety PL e, SIL 3, category 4 (EN ISO 13849-1 and IEC 61508)​
Standard bar code tapesHeight: 25 mm, 47 mm Length: up to 200 m
Status signal of reading qualityFor early detection of soiling

器件图片

技术资料