Power
1) Voltage Rating600 V RMS
Environment and package
1) Temperature Range-40 to 90°C(static), -5 to 90°C (dynamic)
Other
(1) Color(s)SLATE
1) Component 11 X 7 COND
(1) PrintALPHANUMERIC NUMBERS - 1-ONE ALTERNATING AND INVERTED
(1) Twists3.2 Twists/foot (min)
1) UL2) CSA International
2) Bend Radius5X Cable Diameter(static), 5X Cable Diameter(dynamic)
2) Capacitance44 pF/ft @1 kHz, Nominal Conductor to Conductor
(2) Jacket SeparatorTissue Tape, 20% Overlap, Min.
(2) OrientationComponents to be arranged from INSIDE LAYER to OUTSIDE LAYER
2) ShieldTinned Copper BRAID Shield,85% Coverage, Nom.
3) California Proposition 65This product may contain substances known to the State of California to cause Cancer or Reproductive Harm, but is exempt from labeling based on the Consent Judgement. See the Alpha Wire website for more information.
3) CEEU Low Voltage Directive 2014/35/EU
3) Ground Capacitance79 pF/ft @1 kHz, Nominal
3) Pull Tension152 Lbs, Maximum
4) Inductance0.18 μH/ft, Nominal
5) Conductor DCR4.1 Ω/1000ft @20°C, Nominal
6) OA Shield DCR2.7 Ω/1000ft @20°C, Nominal
90°C / 600 V RMS90°C / 600 V RMS
a) 3000 FT36 x 14 x 12 Continuous length
a) Color(s)SLATE
AWM/STYLE 2587C(RU) AWM I/II A/B
b) 1000 FT24 x 14 x 12 Continuous length
b) Jacket SeparatorTissue Tape, 20% Overlap, Min.
c) 500 FT18 x 14.25 x 8 Continuous length
c) Cabling7 COND Cabled
ColorBLACK #1
Cond1
c) PrintALPHA WIRE-* P/N 65607CY 7C 16 AWG XTRAGUARD(R) FLEXIBLE CONTROL CABLE RU AWM 2587 CLASS K OR CRU AWM I/II A/B FT1 90C 600V CE ROHS (SEQ FOOTAGE) * = Factory Code
d) 100 FT12 x 5.94 x 5 Continuous length
Electrical Properties(For Engineering purposes only)
PackagingFlange x Traverse x Barrel (inches)

Documents