Technical parameters

Power
[Abs] Electrostatic discharge voltage(IEC61000-4-2) (V ESD)+/-12 kV
[Abs] Peak pulse current (IEC61000-4-5) (I PP)2.5 A
[Elec] Clamp voltage (Based on IEC61000-4-5) (Typ.) (V C)22 V
[Elec] Reverse Breakdown Voltage (Min) (V BR)15.3 V
[Elec] Reverse Current (Max) (I R)0.5 μA
[Elec] Working peak reverse voltage (Max) (V RWM)12 V
[Elec] Zener Voltage (Typ.) (V Z)15.3 V
AC and DC characteristics
[Elec] Dynamic impedance (Max) (Z Z)35 Ω
Environment and package
[Desc] RoHS Compatible Product(s) (#)Available
Other
[Desc] ApplicationGeneral-purpose
[Desc] ConfigurationUnidirectional
[Desc] Internal ConnectionSingle
[Desc] Number of Circuits1
[Desc] Number of Protected Lines1
[Elec] Dynamic resistance (Typ.) (R dyn)0.6 Ω
[Elec] Total Capacitance (Typ.) (C T)10 pF

Documents