All alternatives

View full report

Technical parameters

Power
Power consumption30W or less
Power supply100, 110, 200 or 220 VAC (rated voltage : ?15+10%, 50/60 Hz)
Environment and package
Ambient temperature-25°C to 55 °C (Non-freezing)
Storage temperature-40°C to 70 °C (Non-condensing)
Other
ALARM output operation modeOutput rating : Relay output 250VAC 5A or less (resistive load)
Ambient humidity35 - 85%RH (Non-condensing)
ConnectionTerminal block
Control outputSingle-hole detection output : Relay output 1c and NPN open collector output (floating) Double-hole detection output : Relay output 1c and NPN open collector output (floating)
DescriptionController
Dielectric withstanding/Insulation resistanceBetween power supply and case Between relay output and case Between relay output and power supply 1500 VAC for 1 minute, 20 MΩ or higher (with 500 VDC) Between open collector output and case Between open collector output and power supply 1000 VAC for 1 minute, 20 MΩ or higher (with 250 VDC)
ModelType
Operation modeOne shot output : duration variable between 0.1-1 second (adjustment volume on panel)
Output ratingRelay output : 250 VAC 5 A or less (resistive load) NPN Open collector output : 30VDC 100mA or less
Protective structureIP40 (with case)
Receiver check inputa (normally open) contact input (short circuiting of Terminals 9 and 10)
Response timeRelay output : 30 ms or less NPN Open collector output : 3ms or less
SAFETY outputRelay output 1a Output rating : 250 VAC 5 A or less (resistive load)
Shock500m/s2/ 3 times each in 3 directions
SWD60For single and double hole detection
TypeFor single and double hole detection
Vibration10-55 Hz / 1.5 mm double amplitude / 2 hours each in 3 directions
WeightApprox. 9 ㎏

Documents