Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| No-load supply current | I 0 | ≤ 75 mA |
| Operating current | I L | 150 mA , short-circuit/overload protected |
| Operating voltage | U B | 15 ... 30 V (including ripple) In supply voltage interval 15 ... 20 V sensitivity reduced to 20% ... 0% |
| Rated operating voltage | U e | 24 V DC |
| Voltage drop | ≤ 3 V |
| Характеристики по постоянному и переменному току | |
| 0 Level ≤ 3 V 1 Level 15 ... 30 V Input impedance typ. 0.9 kΩ Number of sensors max. 10 | 0 Level | ≤ 3 V | 1 Level | 15 ... 30 V | Input impedance | typ. 0.9 kΩ | Number of sensors | max. 10 |
| Input impedance | typ. 0.9 kΩ |
| Repeat accuracy | R | ± 15 mm |
| Ripple | ≤ 10 % |
| Switch-on delay | 800 ms |
| Time delay before availability | t v | 280 ms |
| Transducer frequency | approx. 60 kHz |
| Условия эксплуатации и корпус | |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Другое | |
| 0 Level | ≤ 3 V |
| 1 Level | 15 ... 30 V |
| Adjustment range | 800 ... 10000 mm |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Connection type | screw terminals , PG 13.5 cable gland |
| Dead band | 0 ... 800 mm |
| Default setting | 800 ... 10000 mm |
| Degree of protection | IP65 |
| Depth | 112 mm |
| Depth 112 mm Diameter 160 mm | Depth | 112 mm | Diameter | 160 mm |
| Diameter | 160 mm |
| Housing | UP 1225 SF/R8 |
| Housing UP 1225 SF/R8 Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam | Housing | UP 1225 SF/R8 | Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| Input/output type | 1 synchronization connection, bidirectional |
| Installation position | any position |
| LED yellow | solid: switching state switch output flashing: misadjustment |
| Linearity error | ≤ 1.5 % |
| Load resistor | > 2 kΩ |
| Mass | 1800 g |
| Number of sensors | max. 10 |
| Output type | 2 switch outputs PNP, NC |
| Permissible cable length | max. 300 m |
| Sensing range | 800 ... 10000 mm |
| Shock resistance | 30 g , 11 ms period |
| Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standards EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 | Standards | EN IEC 60947-5-2:2020 IEC 60947-5-2:2019 EN 60947-5-7:2003 IEC 60947-5-7:2003 |
| Standard target plate | 100 mm x 100 mm |
| Transducer | epoxy resin/hollow glass sphere mixture; polyurethane foam |
| UL approval | cULus Listed, General Purpose |
| Vibration resistance | 10 ... 55 Hz , Amplitude ± 1 mm |
Изображения