Pepperl+Fuchs, Inc.Германия
88892
ПроизводитсяRead head, RS-485 interface, with RS-485 terminal resistor
Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| Operating voltage | U B | 10 ... 30 V DC |
| Power consumption | P 0 | 11 VA at 24 V DC |
| Характеристики по постоянному и переменному току | |
| Noise immunity | DIN EN 61000-6-2 , DIN EN 12016 |
| Resolution | ± 0.4 mm (1,250 positions/m) |
| Условия эксплуатации и корпус | |
| Operating temperature | -40 ... 60 °C (-40 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Другое | |
| Address | 0 |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Connection type | 5-pin, M12 x 1 connector |
| CSA approval | cCSAus Certified, General Purpose Class 2 power source |
| Data flow indicator | LED yellow: data communication active |
| Data output code | binary code |
| Degree of protection | IP67 / IP69 |
| Diagnostic Coverage (DC) | 0 % |
| Emitted interference | DIN EN 61000-6-4 , DIN EN 12015 |
| Error indicator | LED red flashing: read head outside of code rail solid on: internal diagnostic test failed |
| Free tolerances to code rail | horizontal: 28 mm ( ± 14 mm ) vertical: 25.5 mm ( +11.5 mm/-14 mm ) |
| Housing | PET , PC (Polycarbonate) |
| Housing PET , PC (Polycarbonate) | Housing | PET , PC (Polycarbonate) |
| Interface type | RS 485 interface |
| Mass | 1000 g |
| Measuring length | max. 314.5 m |
| Mission Time (T M ) | 10 a |
| MTTF d | 60 a |
| Note | The reader must not be operated without the protective housing! |
| Operation indicator | LED green: power on |
| Passage speed | v | ≤ 12.5 m/s |
| Photobiological safety | exempt group according to EN 62471:2008 |
| Protocol | 1 , 2 |
| Shock resistance | DIN EN 60068-2-27, half sine 30 g, 18 ms |
| Termination | with RS 485 termination |
| Transfer rate | 62.5 kBit/s |
| Vibration resistance | DIN EN 60068-2-6, sine, 5 g, 10 - 2000 Hz, 10 cycles |