Thunder Components Ltd. is your leading industry resource for manufacturers and product information on the wirewound resistors. Our organization has always aimed at keeping our clients ahead of the curve and thus makes every possible effort in this direction.
Все аналоги
Полный отчётТехнические параметры
| Питание | |
|---|---|
| Insulation voltage | 1000VAC; 2000VAC; 4500VAC | △R ≤ ±(0.2%R + 0.05Ω) |
| Характеристики по постоянному и переменному току | |
| Vibration high frequency | Frequency 10~200Hz, peak 20g, 2 directions, time 6 hours | △R ≤ ±(0.2%R + 0.05Ω) |
| Условия эксплуатации и корпус | |
| Moisture load Life | Tenp 40°C moisture 95: 1/10X wattage fating (1.5HrON-0.5HrCFF) •Repeat 1C00Hr | △R±(0.5X+0.05Ω)MAX |
| Moisture proof | △R ≤ ±(1.0%R + 0.05Ω) |
| Moisture Resistance | Tenp 40°C moisture 95:DC100v5COHr | △R±(0.5X+0.05Ω)MAX |
| Temperature | 250°C, 2 hours | △R ≤ ±(0.5%R + 0.05Ω) |
| Thermal shock | Work at rated voltage until thermal stability, then place at -55°C for 15 minutes | △R ≤ ±(0.5%R + 0.05Ω) |
| Другое | |
| 10W | 13 | 15 | 20 | 42 | 10.5 | 23 | 10.5 | 1.7 | 5 | 3.5 | 3 | 1.6 | 1.3 | 10.5 |
| 25W | 18.5 | 20 | 27 | 52 | 15 | 29 | 15 | 2 | 7 | 4.5 | 3.5 | 2.5 | 2 | 12 |
| 35W | 25 | 22 | 34 | 57 | 15 | 29 | 15.5 | 2 | 7.5 | 4.5 | 3.5 | 2 | 2 | 12 |
| 50W | 40 | 22 | 50 | 74.5 | 15 | 29 | 15.5 | 2 | 7 | 5 | 3.5 | 3.5 | 2 | 12 |
| 80W | 40 | 21 | 75 | 99.5 | 15 | 29 | 15.5 | 2 | 7.5 | 17.5 | 3.5 | 2 | 2 | 11.5 |
| A ±1 | B ±1 | C ±1 | D ±1.5 | E ±0.5 | F ±0.5 | G ±0.5 | H ±0.5 | J ±0.5 | K ±0.5 | L ±0.5 | M ±0.5 | N ±0.5 | P ±2 |
| AH | 5W | 11 | 13 | 15 | 32 | 8.5 | 17 | 8 | 1.3 | 4.5 | 2 | 2.4 | 0.7 | 27.5 |
| AH-10 | RE65 | 10 | 0.02-6k | 0.03-2.3k | 245 | 180 | 7 | 152X102X51Xlt |
| AH-100 | RE77 | 100 | 0.4-50k | 0.12-25k | 1900 | 1340 | 450 | 305X305X3t |
| AH-100WM | 40 | 22 | 70 | 94.5 | 15 | 28 | 15 | 2 | 6.8 | 3.5 | 4 | 2 | 2 | 13 |
| AH-25 | RE70 | 25 | 0.012-15k | 0.02-5.5k | 500 | 300 | 15 | 178X127X51Xlt |
| AH-250 | RE80 | 250 | 0.6-80k | 0.15-40k | 2500 | 1750 | 800 | 305X305X3t |
| AH-5 | RE60 | 5 | 0.05-3k | 0.1-1k | 120 | 70 | 3 | 152X102X51Xlt |
| AH-50 | RE75 | 50 | 0.01-40k | 0.02-12k | 1300 | 500 | 33 | 305X305X1.5t |
| AH-75WM | 39 | 22 | 60 | 85 | 15 | 28 | 15 | 2 | 6.8 | 3.5 | 3.5 | 2 | 2 | 12.5 |
| AN Inauctive | AHN Norrductie | AH | AHN |
| Dielectric | AH-5 AH-10 AH-25 1000V AH-50 1500V AH-100 AH-250 2500V | △R±(0.2X+0.05Ω)MAX |
| Ensulation Resistance | Under the same test condition of Dielectric Strength. Load DC5DCV and neasure the InsulationR. | 1000mΩmin |
| Heat Resistance | 275°C 2Hr | △R±(0.5X+0.05Ω)MAX |
| Load Life | Load Rating (Chassismounted) (1.5Hr ONO.5Hr OFF)Reapeat 1C00Hr | △R±(1.5X+0.05Ω)MAX |
| Load life | Rated power, working for 1000 hours at 25°C, with 1.5 hours on and 0.5 hours off | △R ≤ ±(1.0%R + 0.05Ω) |
| Model | Power | Dimensions (mm) |
| Parameters | Test Conaitions | Wartage Rating |
| Pilot projects | Experimental condition | Requirements |
| Pulse resistant | 100g, 6 ms, 10 times | △R ≤ ±(0.2%R + 0.05Ω) |
| Shortime OverLoad | 5Xmattagerating• Ssec. | △R±(0.5X+0.05Ω)MAX |
| Short time overload | 5 times rated power for 5 seconds | △R ≤ ±(0.5%R + 0.05Ω) |
| Terminal Strength | (1) Pull Test(30sec Nin) AH-51kg.Ah-102.3kg.AH-25.AH-504.5kg (2) Torque Test(5~15sec) AH-10027kg•cm. AH-250 36kg-cm | △R±(0.2X+0.05Ω)MAX |
| Terminal tensile strength | Tensile force: 22.2N, 44.4N Time: 30S Torque: 2.7N·m, 3.6N·m | △R ≤ ±(0.2%R + 0.05Ω) |
| Type | MIL Style | Wartage Rating | Resistance Range(Ω) | MAX Wcring(V) | (g)MAX Weight | Proper heatisink (aluminumctassis) |
| V10r at ton | 10c/s-50c/s-10c/s(1min)-2Hr each of Paralleled and right angle. | △R±(0.5X+0.05Ω)MAX |